Customer Service 800-243-3232
Please sign in or create a new account. Forgot password?
Oxford Benchmate
Eppendorf Research Plus
Eppendorf Repeater M4
CAPP MAESTRO
CAPP Aero Multichannel Pipette
CAPP 384 Liquid Handling
CAPP Tempo Controller
Biohit Picus Electronic Pipette
AccuPet Pro Single Channel Pipette
Evolution Advanced Pipettes
Rainin LTS
Accupet
Brandtech
CAPP
Corning
Drummond
Eppendorf
Gilson
Hamilton
Heathrow
Hirschmann
Integra Viaflo
Jencons
Labnet
Matrix
Nichiryo
Oxford
Rainin
Sartorius (Biohit)
Socorex/Wheaton
ThermoFisher
VistaLab
VWR
Transfer Pipettes
Single Channel Pipetting
Fixed Volume Pipetting
Multichannel Pipetting
Electronic Pipetting
384 Liquid Handling
Repeaters
Motorized Pipet Controllers
Positive Displacement Pipettes
Bottle Top Dispensers
Pasteur Pipettes
Filter Tips
Bulk Tips
Eclipse Reloads
Racked Tips
Racked Sterile Tips
Low Retention Tips
Wide Bore Tips
Macro 5 and 10 mL
Gel Loading
Tips for Rainin LTS
Eppendorf Combitips
Serological Pipettes
Eppendorf Dualfilter Tips
Robotic Tips
ThermoFisher Tips for Rainin
Tips for Biohit 1200uL pipette
Tips for 384 Pipettes
BrandTech PD-Tip Syringe Tips
Repeater Syringe Tips
Positive Displacement
Axygen
Brand
Oxford Tip Promotions
Nichyrio
Pipette.com
Thermo (MBP)
Oxford Lab Products
Microcentrifuge Tubes
Eppendorf Microcentrifuge Tubes
Centrifuge Tubes
Conical Tubes
PCR Tubes
PCR Strip Tubes
Cryogenic Vials
Screw Cap Tubes
Culture Tubes
Cluster Tubes
Chromatography and Scintillation Vials
Cuvettes
Tube Racks and Holders
96 Well Plates
384 Well Plates
Deep Well Plates
Real Time QPCR Plates
Sealing Films, Mats, Accessories
Eppendorf Microplate
Eppendorf Assay Plate
Glass Bottom Plates
Cell Culture Consumables
Cell Culture Dishes, Flasks & Plates by NEST
CELLTREAT Products
Cell Strainers & More By MTC Bio
Globe Scientific Products
Petri Dishes
Immunoassay Plates by BrandTech
Accessories for Cell & Bacteria Culture
WHEATON CELLine Bioreactors
Autoclaves & Sterilization Equipment
Balances
Balances (High-Performance Cubis)
Bar Code Readers
Centrifuges
Concentrators
Electrophoresis, Gel Tanks, and Power Supplies
ELISA Washers
Fluid Aspiration Systems
Freezers & Refrigerators
Homogenizers
Incubators
Magnetic Stirrers & Hotplates
Microscopes
Moisture Analyzers
Orbital Shakers
pH Meters
Plate Shakers
Rockers
Rotary Evaporators
Shaking Incubators
Specialty Equipment
Spectrophotometers & Plate Readers
Thermocyclers
ThermoMixers
Transilluminators & Imaging Systems
Tube Rollers & Rotators
Vacuum Pumps & Peristaltic Pumps
Vortex Mixers
Water & Dry Baths
Water Purification Systems
Weighing Boats
Oxford Lab Equipment
Eppendorf Centrifuges
Vortex Genie
Sartorius Balances
Eppendorf New Brunswick Shakers
Benchmark Centrifuges
Labnet Centrifuges
BrandTech Vacuum Pumps
Ohaus Balances & Equipment
CAPP Lab Equipment
Radwag Equipment
See All Equipment
Autoclave Tape & Biohazard Bags
Cryogenic Storage & Freezer Boxes
Filtration Products
Glass Bottles
Gloves & Safety
Medical & Laboratory Tape
Microscope Slides
Labels & Markers
Parafilm, Sealing Film & Foil
PCR Reagents
Pipette Stands
Plastic Bottles
Reagent Reservoirs
Sample Cups & Storage
Task Wipes & KimWipes
Tube Racks & Holders
Volumetric Labware
Weighing Boats & Spatulas
Wheaton Products
T-Shirts & Giveaways
ISO 17025 Calibration& Pipette Repair
Get Shipping Label
Download Calibration Order Form
Order Pipette Calibration Service
Free shipping when you send in 5 or more pipettes for calibration
Pipette.com is an ISO 17025 Accredited Calibration Facility that calibrates and repairs all pipette brands and models.
Pipettes undergo a Leakage Test, Functional Test, and Calibration Check are performed with 4x2 weighings
Each pipette is completely dissembled, cleaned inside & out, pistons are polished & re-greased, and seals &/or o-rings are replaced as needed (as specified by the manufacturer, make, & model) then reassembled. Parts that can wear-out are proactively replaced
Instantly access a pipette's history, calibration reports and calibration due date on line with our free pipette management tool
Every pipette undergoes 4x2 weighings (2 at low volume & 2 at high volume as specified by manufacturer requirements) in an environmentally controlled calibration facility. Extended calibration points & weighings, and individual channel calibration for multichannel pipettes are available upon request
Median point (4 weighings) can be added to any calibration order
Extended Measurements takes 10 measurements at 2 data points (10×2) to provide more statistical data compared to the 4×2 weighings
Each channel of the multichannel pipette is individually adjusted, weighed, and calibrated. Recommended for precise, quantitative work
Removes existing DNA and RNA contamination, such as over aspirated oligonucleotides
Each Report provides detailed pipette information, mean, standard deviation, and variance of weighings, pipette performance status listed as Pass/ fail, lab conditions during the calibration process, list of parts used in repair, computer-generated barcode linking to online report
Every serviced pipette receives a calibration or verification sticker with a scannable barcode and comprehensive information including the calibration date, next calibration due date, and serial number. Optional information such as user, equipment number and location can also be included on the label
You can choose to be notified via email 4 weeks to 6 weeks before the pipette calibration due date
Includes all of the features of the complimentary report plus the individual weighings in addition to the mean, a dedicated certificate for each pipette, detailed information on the equipment utilized by Pipette.com, and detailed technician information
1 Business day pipette calibration turn-around is available for $10 per pipette
It is a process of examining and/or adjusting the pipettes to the true value by comparison to the standard which is set by the manufacturer of that said pipette. The standard in this case is the pipetting range set by the pipette manufacturer to be accurate and precise at low volume and high volume of the pipette. At Pipette.com, we perform metrology based pipette calibration; Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes
Metrology is defined as a science of measurement. Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes. If this standard is not followed there cannot be a statistical guarantee that your results are accurate to true standards. Science is based on reproducible results. When reproducible results cannot be achieved all work is voided. Thus, scientists must strive that all of their work is reproducible. In order to achieve reproducibility scientists must have accurate and precise equipment. Pipettes are the cornerstone of all research, thus they must always be precise and accurate. In order to achieve this scientists must choose pipette service providers that follow strict metrology guidelines. Providers whose equipment is also calibrated and follows strict NIST rules can provide accurate and precise results giving you informative data on the status of your work and your pipette. Without metrology based calibration one cannot statistically say if the pipette is truly within range, it is simply an assumption using an uncertified piece of equipment
Yes, our technicians are trained by manufacturers and receive on-going training
Yes, we can calibrate Rainin pipettes and repair Rainin pipettes
Yes, we can repair Pipet-Aids and motorized controllers
Preventative Maintenance (PM) is a step in the calibration process that greatly enhances the longevity of your instrument. PM includes full disassembly, interior & exterior cleaning, piston polishing & re-greasing, and new seals/o-rings are replaced as needed. An in-depth PM process helps keep your pipettes operating at peak performance in between your regularly scheduled calibration service dates
No, we do not offer any onsite services due to limited control of environmental conditions (i.e. temperature, humidity, air flow, and direct sunlight) and use the proper equipment (ultra-micro balances situated on marble tables). The American Association for Laboratory Accreditation (A2LA), published a policy in 2012 stating that higher measurement uncertainties are expected from onsite calibration. View that policy here: A2LA Policy P104
We recommend adding individual channel calibration for your multichannel pipette if you need each channel to be precise and accurate (such as when preforming RT-PCR, ELISA, ECL and Bioassays). This means each channel is individually adjusted, weighed, and calibrated. To add this to any pipette calibration service, check the box for “Multi-Channel Readings (per channel) on the “Pipette Service Order Form”
We provide free repair estimates once the broken pipette is in our calibration facility. We only charge you for pipette calibration and replacement parts
Have you used our calibration or repair services? Tell us how we did in this short survey!
Are you sure?