Attention! You've accidentally stumbled across our test site! To place an order, please go to https://pipette.com.

Customer Service 800-243-3232

Cart Favorites
x
 

PIPETTE CALIBRATION & SERVICE FROM PIPETTE.COM

Qualer_Calibration_Banner_Web
Qualer_Calibration_Promo_Banner_350x203

FREE SHIPPING

Free shipping when you send in 5 or more pipettes for calibration

PIPETTE.COM CALIBRATION FACILITY

Pipette.com is an ISO 17025 Accredited Calibration Facility that calibrates and repairs all pipette brands and models.

button_order-pipette-calibration (1)
button_get-calibration-quote
button_request-more-information
10Tips_Pipetting

SERVICES WE PROVIDE

 

 

Verification

Calibration

Calibration PLUS

Is This Right For My Lab?

1. Are there new pipettes that require a calibration due date?

2. Do you need to demonstrate your pipettes are within manufacturer specifications in between calibration cycles?
1. Do you want to extend the longevity of your pipettes?

2. Are your pipettes routinely utilized in the laboratory?
1. Do you verify your pipettes in the lab in between calibration cycles?

2. Is your laboratory a GLP, CLIA, manufacturing, or audited laboratory?

3. Are you obtaining odd results that could be attributed to incorrect volumes?

Calibration Overview

Pipettes are confirmed to be within or out of manufacturer’s specifications in an environmentally controlled facility. Pipettes undergo preventive maintenance (PM) and calibrated to manufacturer specifications. Pipettes undergo verification first, and then preventive

Benefits

Pipettes are confirmed to be within or out of manufacturer’s specifications. This is also a cost-effective way to obtain a calibration due date on new pipettes Preventative maintenance (PM) proactively replacing parts that are known to fail before they affect the performance of the pipette. Many pipettes that are out of tolerance fail because PM parts have worn out. You can demonstrate your pipettes are within calibration range before they undergo preventative maintenance and calibration. Alternatively, if your pipettes are out of tolerance, you can adjust future calibration intervals to be closer together.

 

CALIBRATION SERVICES GLOSSARY

 

Pipettes undergo a Leakage Test, Functional Test, and Calibration Check are performed with 4x2 weighings

Each pipette is completely dissembled, cleaned inside & out, pistons are polished & re-greased, and seals &/or o-rings are replaced as needed (as specified by the manufacturer, make, & model) then reassembled. Parts that can wear-out are proactively replaced

Instantly access a pipette's history, calibration reports and calibration due date on line with our free pipette management tool

Every pipette undergoes 4x2 weighings (2 at low volume & 2 at high volume as specified by manufacturer requirements) in an environmentally controlled calibration facility. Extended calibration points & weighings, and individual channel calibration for multichannel pipettes are available upon request

Median point (4 weighings) can be added to any calibration order

Extended Measurements takes 10 measurements at 2 data points (10×2) to provide more statistical data compared to the 4×2 weighings

Each channel of the multichannel pipette is individually adjusted, weighed, and calibrated. Recommended for precise, quantitative work

Removes existing DNA and RNA contamination, such as over aspirated oligonucleotides

Each Report provides detailed pipette information, mean, standard deviation, and variance of weighings, pipette performance status listed as Pass/ fail, lab conditions during the calibration process, list of parts used in repair, computer-generated barcode linking to online report

Every serviced pipette receives a calibration or verification sticker with a scannable barcode and comprehensive information including the calibration date, next calibration due date, and serial number. Optional information such as user, equipment number and location can also be included on the label

You can choose to be notified via email 4 weeks to 6 weeks before the pipette calibration due date

Includes all of the features of the complimentary report plus the individual weighings in addition to the mean, a dedicated certificate for each pipette, detailed information on the equipment utilized by Pipette.com, and detailed technician information

1 Business day pipette calibration turn-around is available for $10 per pipette

 
 

FREQUENTLY ASKED QUESTIONS

 

It is a process of examining and/or adjusting the pipettes to the true value by comparison to the standard which is set by the manufacturer of that said pipette. The standard in this case is the pipetting range set by the pipette manufacturer to be accurate and precise at low volume and high volume of the pipette. At Pipette.com, we perform metrology based pipette calibration; Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes

Metrology is defined as a science of measurement. Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes. If this standard is not followed there cannot be a statistical guarantee that your results are accurate to true standards. Science is based on reproducible results. When reproducible results cannot be achieved all work is voided. Thus, scientists must strive that all of their work is reproducible. In order to achieve reproducibility scientists must have accurate and precise equipment. Pipettes are the cornerstone of all research, thus they must always be precise and accurate. In order to achieve this scientists must choose pipette service providers that follow strict metrology guidelines. Providers whose equipment is also calibrated and follows strict NIST rules can provide accurate and precise results giving you informative data on the status of your work and your pipette. Without metrology based calibration one cannot statistically say if the pipette is truly within range, it is simply an assumption using an uncertified piece of equipment

Yes, our technicians are trained by manufacturers and receive on-going training

  • Single channel manual pipettes and electronic pipettes
  • Multichannel manual pipettes and electronic pipettes
    • 4-channel pipettes
    • 6-channel pipettes
    • 8-channel pipettes
    • 12-channel pipettes
    • 16-channel pipettes
    • 48-channel pipettes
    • 64-channel pipettes
    • 96-channel pipettes
  • Bottletop dispensers
  • Burettes
  • Motorized controllers
  • Positive displacement pipettes
  • Repeaters

Yes, we can calibrate Rainin pipettes and repair Rainin pipettes

  • Accupet Pipettes
  • Biohit Pipettes
  • BrandTech Pipettes
  • CAPP Pipettes
  • Cole-Palmer Pipettes
  • Drummond Pipettes
  • Eppendorf Pipettes
  • Falcon Pipettes
  • Gilson Pipettes
  • Hamilton Pipettes
  • Heathros Pipettes
  • Hirschmann Pipettes
  • Jencons Pipette
  • Labnet Pipettes
  • Matrix Pipettes
  • Nichiryo Pipettes
  • Oxford Lab Products
  • Rainin Pipettes
  • Sartorius Pipettes
  • Socorex Pipettes

Yes, we can calibrate Rainin pipettes and repair Rainin pipettes

Yes, we can repair Pipet-Aids and motorized controllers

Preventative Maintenance (PM) is a step in the calibration process that greatly enhances the longevity of your instrument. PM includes full disassembly, interior & exterior cleaning, piston polishing & re-greasing, and new seals/o-rings are replaced as needed. An in-depth PM process helps keep your pipettes operating at peak performance in between your regularly scheduled calibration service dates

No, we do not offer any onsite services due to limited control of environmental conditions (i.e. temperature, humidity, air flow, and direct sunlight) and use the proper equipment (ultra-micro balances situated on marble tables). The American Association for Laboratory Accreditation (A2LA), published a policy in 2012 stating that higher measurement uncertainties are expected from onsite calibration. View that policy here: A2LA Policy P104

We recommend adding individual channel calibration for your multichannel pipette if you need each channel to be precise and accurate (such as when preforming RT-PCR, ELISA, ECL and Bioassays). This means each channel is individually adjusted, weighed, and calibrated. To add this to any pipette calibration service, check the box for “Multi-Channel Readings (per channel) on the “Pipette Service Order Form”

We provide free repair estimates once the broken pipette is in our calibration facility. We only charge you for pipette calibration and replacement parts

button_order-pipette-calibration (1)
button_get-calibration-quote
button_request-more-information

 

Have you used our calibration or repair services? Tell us how we did in this short survey!